Inch Mile…..B-vents
Just so were clear…… Crystal clear….CUZ U CAN’T HANDLE THE TRUTH! Great movie if you have n’t seen it. Jack N and Tom C, Demi M. Again today I ran across a gas vent in contact with combustible materials. On … Continue reading →
Just so were clear…… Crystal clear….CUZ U CAN’T HANDLE THE TRUTH! Great movie if you have n’t seen it. Jack N and Tom C, Demi M.
Again today I ran across a gas vent in contact with combustible materials.
Gas B-vent touching roof decking; gee I guess they shoulda cut that decking out to the line they drew….bubba go get the sawz all…..its the one with that long blade yup kinda looks like a machine gun.
On multiple occasions that I have called this out the sellers have come back saying “Its a double wall pipe and is acceptable as is”…..Yes B-Vents are double wall; but an inch of separation is still required as indicated on the STICKER stuck to the vent.
If ya dust off your code book you’ll see that a single wall gas vent requires 6″ of clearance to combustibles. That’s why you don’t see them very often.
Seeing KNOWING Caring Inspector Bill Carlson