Friends….I will also add to the “Bill Knows Codes” post; in general, reading and interpreting and then applying codes is not easy.  It is something I have developed a knack for going back to my refinery engineering days with Exxon.  … Continue reading →

Friends….I will also add to the “Bill Knows Codes” post; in general, reading and interpreting and then applying codes is not easy.  It is something I have developed a knack for going back to my refinery engineering days with Exxon.  ANSI B31.3 Piping; ASME Pressure Vessel, and API 650 Tankage codes are the codes of my past……and IRC is my current code.  Looks like I’m batting 1000.  Below is another code interpretation from Gary Nelson at ICC.  This is concerning unanchored wall sills nailed to anchored main sills that I see all the time on houses built on hills in the Nashville,  Brentwood, Franklin, area.  My contention is that the wall sill must be anchored also to meet framing hold down requirements. Looks like that is the case…..cuz nailing in never gonna equal the hold down strength of 1/2″ anchor bolts.

Main sill is anchored to foundation properly......Wall sill is face nailed to the main sill.....Does it meet code?

Email from ICC:

Mr. Bill Carlson

Private Home Inspector

carlson.inspect@gmail.com

 

RE:     Sections R403.1.6, R403.1.6.1, R602.3, R602.10.6 and R602.11 along with

Figures R403.1(1) and R602.3(1) and Table R602.3(1) of the

ICC International Residential Code/2009

We understand your situation involves a single-family residence or its accessory structure.  A 2 x 8 sill plate has been anchored bolted to the continuous foundation wall as required by Section R403.1.6.  The 2 x 4 wood-framed exterior wall, with its own integral bottom plate or sole plate, has then been installed over the larger sill plate.  We further understand that the smaller bottom plate has only been face nailed to the larger sill plate.  You are specifically asking whether the smaller bottom plate should have also been anchored bolted to the foundation wall.

 

The intent of the code is that the exterior walls and the continuous footings that they sit upon will safely transmit all of the environmental and live loads acting on the superstructure down to the underlying supporting soils.  Section R403.1.6 states that not only the sill plates but also the walls that are supported directly on the continuous foundations must be properly anchored to the foundation.  In this specific case, structural design calculations must be submitted that demonstrate the face nails used to fasten the bottom plate of the wood-framed exterior wall to the larger sill plate are equivalent to 1/2” diameter anchor bolts spaced every 6’ on center.  Otherwise, the anchor bolts must fasten both plates to the foundation.  The specific details and arrangement of these exterior walls and their anchorage must be carefully reviewed and approved by the local building official as part of the building construction permit process.

 

We hope this answers your concerns in full.  If you have any further questions, please call.  Code opinions issued by the ICC staff are based on ICC published codes and do not include any local, state or federal codes, policies or amendments.  These opinions are based on the information which you have provided.  We have made no independent effort to verify the accuracy of this information nor have we conducted a review beyond the scope of your questions.  These opinions do not imply approval of an equivalency, specific product, specific design or specific installation and cannot be published in any form implying such approval by the International Code Council.  As these opinions are only advisory, the final decision is the responsibility of the designated authority charged with the administration and enforcement of this code.

 

Very truly yours,

 

Gary L. Nelson, P.E., C.B.O.

Senior Staff Engineer

A & E Plan Review Dept.

International Code Council, Inc.

Chicago District Office

1-888-ICC-SAFE, ext. 4311

August 29, 2022
Did you waive your inspection in a multi offer situation? New construction or older home it’s time to find out what you bought and where to start! STILL providing the most THOROUGH home inspection and DETAILED inspection report in a 100 mi radius to Nashville after 20 years. See 12 full example reports at www.seeingknowingcaring.com ! This was my discovery at a recent inspection: Seeing Knowing Discovering the fungal Nirvana Inspector Bill Carlson
January 18, 2021
Home Inspection Structural Comment; Not for the Squeamish
June 26, 2020
Repair: The original fireplace chimney was essentially built into the solid masonry wall structure of the home located on the interior side of the wall (chimney not visible at exterior). The chimney no longer passes through the roof line and the chimney is not suitable for use. The top of the chimney was demo'd below the roof line elevation but was not blocked off and air sealed in the attic or at the top of the fireplaces. Currently, free air transfer occurs between the attic and living room and attic and basement as a result and is a significant energy efficiency issue bringing air with attic conditions into the home. When the HVAC system at the 1st level turns on, attic air is pulled from the attic down the flue into the living room. The attic temperature was approx. 100 deg F at the time of inspection. Loose brick is also present at the top of the flues and could be a falling hazard down the flue if dislodged. A chimney/fireplace technician should be contacted to properly block off and air seal the chimney flues and address debris. Seeing Knowing Throwing money away Inspector Bill Carlson
home inspection report nashville, tn
By Bill Carlson December 18, 2019
The single ply roofing membrane could not be inspected as the inspector did not have proper footwear. A licensed roofing contractor should be contacted to evaluate and repair as needed.
code check nashville tn
By Bill Carlson December 18, 2019
The biggest benefit of getting a home inspection in Nashville, TN is ensuring your future home meets city codes. Call Carlson Home Inspection to find out!
copper gutters nashville tn
By Bill Carlson February 16, 2018
Check out the copper gutters we have had installed on our home in Nashville, TN. Carlson Home Inspection offers home inspection services in Nashville, TN.
home inspection nashville tn
By nashvilleshomeinspector February 1, 2018
In beautiful and scenic Green Hills today. A couple of months ago I came back to my shoes (I inspect interiors shoeless to respect sellers clean houses and get a better floor feel) and the Seller’s cat gave me a … Continue reading →
melted wax rings
By nashvilleshomeinspector January 20, 2018
I see a lot of tankless water heaters in unheated garages in Nash Vegas. We might want to rethink that! It DOES get cold here for extended periods of time. Seeing Knowing Breaking the bad news Inspector Bill Carlson
By nashvilleshomeinspector January 18, 2018
In beautiful ( and wicked cold) Green Hills today………. Seeing Knowing Mixing a shocking Mojito Inspector Bill Carlson
ice scraper with level
By nashvilleshomeinspector January 12, 2018
When the window scraper fails you, sometimes you just got to improvise! Carlson Home Inspection in Nashville, TN braves this winter weather!
Show More