How and Why? Not addressed in most Home Inspections.

nashvilleshomeinspector • May 15, 2013

From a recent report: •Repair: The floor structure exhibits sagging and movement at the kitchen area and above this space at the 2nd level bathroom/hall. 2nd level doors are obstructed from closing with interference in areas and do not latch … Continue reading →

From a recent report:

•Repair: The floor structure exhibits sagging and movement at the kitchen area and above this space at the 2nd level bathroom/hall. 2nd level doors are obstructed from closing with interference in areas and do not latch with wall cracking observed throughout as well. This is considered evidence of movement. This is likely a result of improper load distribution of 2nd level loads through the home to grade. The 2nd level ceiling joists are oriented east-west which causes the 2nd level hallway wall to be load bearing. This load bearing wall is stacked directly over the kitchen cabinet wall at the 1st level causing this wall to be load bearing as well. The 1st level floor joists system is oriented conversely to the 2nd level ceiling joists; north-south. As a result, the 2nd level ceiling and both wall loads in the upper sections of the building bear on a single parallel oriented joist visible in the unfinished basement area. This is an original design defect. A metal screw jack has been installed to mitigate this issue and is insufficient and improper (See photo 4 page 7). These supports also are not acceptable in permanent support as they do not meet requirements for steel columns; 3” dia and standard weight pipe thickness. Other dead load including HVAC duct work suspended from the flooring structure and kitchen cabinets may have exacerbated the situation. It is also noted the kitchen/laundry area appears to have been reconfigured with a bathroom eliminated and laundry facilities added. A wall may have been removed in the kitchen as part of this reconfiguration as there is a drywall boxed out section at the ceiling that may or may not contain a header. If so, if the header is of insufficient size this also may be a factor in the floor structure distress at the 2nd level. Repairs are needed to reduce the potential for future movement. A licensed structural engineer should be contacted to evaluate and specify a repair. Repair work should be performed by a qualified licensed contractor.

Did your home inspector put this much thought into your sagging floor?……Or did he comment “The floor is sagged. A licensed structural engineer should be contacted to evaluate.”

One of the benefits of having a home inspector/engineer perform your inspection. The connection between cause and effect.

Seeing Knowing Caring Inspector Bill Carlson

August 29, 2022
Did you waive your inspection in a multi offer situation? New construction or older home it’s time to find out what you bought and where to start! STILL providing the most THOROUGH home inspection and DETAILED inspection report in a 100 mi radius to Nashville after 20 years. See 12 full example reports at www.seeingknowingcaring.com ! This was my discovery at a recent inspection: Seeing Knowing Discovering the fungal Nirvana Inspector Bill Carlson
January 18, 2021
Home Inspection Structural Comment; Not for the Squeamish
June 26, 2020
Repair: The original fireplace chimney was essentially built into the solid masonry wall structure of the home located on the interior side of the wall (chimney not visible at exterior). The chimney no longer passes through the roof line and the chimney is not suitable for use. The top of the chimney was demo'd below the roof line elevation but was not blocked off and air sealed in the attic or at the top of the fireplaces. Currently, free air transfer occurs between the attic and living room and attic and basement as a result and is a significant energy efficiency issue bringing air with attic conditions into the home. When the HVAC system at the 1st level turns on, attic air is pulled from the attic down the flue into the living room. The attic temperature was approx. 100 deg F at the time of inspection. Loose brick is also present at the top of the flues and could be a falling hazard down the flue if dislodged. A chimney/fireplace technician should be contacted to properly block off and air seal the chimney flues and address debris. Seeing Knowing Throwing money away Inspector Bill Carlson
home inspection report nashville, tn
By Bill Carlson December 18, 2019
The single ply roofing membrane could not be inspected as the inspector did not have proper footwear. A licensed roofing contractor should be contacted to evaluate and repair as needed.
code check nashville tn
By Bill Carlson December 18, 2019
The biggest benefit of getting a home inspection in Nashville, TN is ensuring your future home meets city codes. Call Carlson Home Inspection to find out!
copper gutters nashville tn
By Bill Carlson February 16, 2018
Check out the copper gutters we have had installed on our home in Nashville, TN. Carlson Home Inspection offers home inspection services in Nashville, TN.
home inspection nashville tn
By nashvilleshomeinspector February 1, 2018
In beautiful and scenic Green Hills today. A couple of months ago I came back to my shoes (I inspect interiors shoeless to respect sellers clean houses and get a better floor feel) and the Seller’s cat gave me a … Continue reading →
melted wax rings
By nashvilleshomeinspector January 20, 2018
I see a lot of tankless water heaters in unheated garages in Nash Vegas. We might want to rethink that! It DOES get cold here for extended periods of time. Seeing Knowing Breaking the bad news Inspector Bill Carlson
By nashvilleshomeinspector January 18, 2018
In beautiful ( and wicked cold) Green Hills today………. Seeing Knowing Mixing a shocking Mojito Inspector Bill Carlson
ice scraper with level
By nashvilleshomeinspector January 12, 2018
When the window scraper fails you, sometimes you just got to improvise! Carlson Home Inspection in Nashville, TN braves this winter weather!
Show More